Home Storages How to see full configurations in of HP SAN?
How to see full configurations in of HP SAN? PDF Print E-mail
Written by Siva   
Tuesday, 23 November 2010 11:53

 

Use "show tech_support" command:

 

 

CLI-2>

 

CLI-2> show tech_support   

 

CLI-2> show version -all

     MSA1500 Firmware Revision:  5.20b1500 (SGA0720002)

                    Build Time:  2007-01-24 16:03:28

     MSA1500 Hardware Revision:  a [AutoRev: 0x030000]

          Fibre Module AutoRev:  0x020000

SCSI I/O Module Bus 0 Revision:  2.02

SCSI I/O Module Bus 1 Revision:  <<NOT INSTALLED>>

SCSI I/O Module Bus 2 Revision:  2.02

SCSI I/O Module Bus 3 Revision:  <<NOT INSTALLED>>

 Fan Control Module A Revision:  2.38

 Fan Control Module B Revision:  2.38

  Box 5  PROLIANT 8LCE     Rev:  2.02 (E0AHMLJ191)

Box 5 Fan Control Module A Rev:  2.38

Box 5 Fan Control Module B Rev:  2.38

  Box 7  PROLIANT 8LCE     Rev:  2.02 (E094MLJ18V)

Box 7 Fan Control Module A Rev:  2.38

Box 7 Fan Control Module B Rev:  2.38

 

Disk Drives:

B  T  L BOX BAY    GB Model                    Rev.     Serial No.

0  4  1   5   1 750.1 Unknown GB0750C4414          HPG  5QD0SQF9

0  4  2   5   2 750.1 Unknown GB0750C4414          HPG  5QDZ0MXS

0  4  3   5   3 750.1 Unknown GB0750C4414          HPG  5QDZ0LXY

0  4  4   5   4 750.1 Unknown GB0750C4414          HPG  5QDZ0GDY

0  4  5   5   5 750.1 Unknown GB0750C4414          HPG  5QD0XNVY

0  4  6   5   6 750.1 Unknown GB0750C4414          HPG  5QD1AEXR

0  4  7   5   7 750.1 Unknown GB0750C4414          HPG  5QD0VNPR

0  4  8   5   8 750.1 Unknown GB0750C4414          HPG  5QDZ0LWX

0  4  9   5   9 750.1 Unknown GB0750C4414          HPG  5QDZ0KSC

0  4 10   5  10 750.1 Unknown GB0750C4414          HPG  5QDZ0KPS

0  4 11   5  11 750.1 Unknown GB0750C4414          HPG  5QD149H3

0  4 12   5  12 750.1 Unknown GB0750C4414          HPG  5QD0VMS8

2  4  1   7   1 750.1 Unknown GB0750C4414          HPG  5QDZ0LE1

2  4  2   7   2 750.1 Unknown GB0750C4414          HPG  5QD0XNL0

2  4  3   7   3 750.1 Unknown GB0750C4414          HPG  5QDZ0KQY

2  4  4   7   4 750.1 Unknown GB0750C4414          HPG  5QD14Q81

2  4  5   7   5 750.1 Unknown GB0750C4414          HPG  5QD13EN4

2  4  6   7   6 750.1 Unknown GB0750C4414          HPG  5QD151ZC

2  4  7   7   7 750.1 Unknown GB0750C4414          HPG  5QD13M08

2  4  8   7   8 750.1 Unknown GB0750C4414          HPG  5QD0X2K5

2  4  9   7   9 750.1 Unknown GB0750C4414          HPG  5QDZ0MY2

2  4 10   7  10 750.1 Unknown GB0750C4414          HPG  5QDZ0KPL

2  4 11   7  11 750.1 Unknown GB0750C4414          HPG  5QD10J40

2  4 12   7  12 750.1 Unknown GB0750C4414          HPG  5QD0WPXC

 

 

CLI-2> show profile

Profile name = Default  (Default) Mode value = (00004005)

 

   Mode 0 = Peripheral Device LUN Addressing

   Mode 1 = Legacy Failover

   Mode 2 = Logical volumes connect as available on Backup Controller

   Mode 3 = Product ID of 'MSA1000 VOLUME' (only if Active-Standby mode)

   Mode 4 = Normal bad block handling

   Mode 5 = Logout selected initiators on TPRLO

   Mode 6 = Fault management events not reported through Unit Attention

   Mode 7 = Do not send FCP response info with SCSI status

   Mode 8 = Do not send Unit Attention on failover

   Mode 9 = SCSI inquiry revision field contains the actual version

   Mode 10 = SCSI inquiry vendor ID='Compaq'

   Mode 11 = Power On Reset Unit Attention generated on FC Login or Logout

   Mode 12 = Ignore Force Unit Access on Write

   Mode 13 = Ignore Target Port on Reservation

   Mode 14 = Active/Standby Operating Mode

 

Profile name = Windows

   Type = Standard Mode value = (00004005)

 

   Mode 0 = Peripheral Device LUN Addressing

   Mode 1 = Legacy Failover

   Mode 2 = Logical volumes connect as available on Backup Controller

   Mode 3 = Product ID of 'MSA1000 VOLUME' (only if Active-Standby mode)

   Mode 4 = Normal bad block handling

   Mode 5 = Logout selected initiators on TPRLO

   Mode 6 = Fault management events not reported through Unit Attention

   Mode 7 = Do not send FCP response info with SCSI status

   Mode 8 = Do not send Unit Attention on failover

   Mode 9 = SCSI inquiry revision field contains the actual version

   Mode 10 = SCSI inquiry vendor ID='Compaq'

   Mode 11 = Power On Reset Unit Attention generated on FC Login or Logout

   Mode 12 = Ignore Force Unit Access on Write

   Mode 13 = Ignore Target Port on Reservation

   Mode 14 = Active/Standby Operating Mode

 

Profile name = Windows (degraded performance)

   Type = Standard Mode value = (00005005)

 

   Mode 0 = Peripheral Device LUN Addressing

   Mode 1 = Legacy Failover

   Mode 2 = Logical volumes connect as available on Backup Controller

   Mode 3 = Product ID of 'MSA1000 VOLUME' (only if Active-Standby mode)

   Mode 4 = Normal bad block handling

   Mode 5 = Logout selected initiators on TPRLO

   Mode 6 = Fault management events not reported through Unit Attention

   Mode 7 = Do not send FCP response info with SCSI status

   Mode 8 = Do not send Unit Attention on failover

   Mode 9 = SCSI inquiry revision field contains the actual version

   Mode 10 = SCSI inquiry vendor ID='Compaq'

   Mode 11 = Power On Reset Unit Attention generated on FC Login or Logout

   Mode 12 = Enforce Force Unit Access on Write

   Mode 13 = Ignore Target Port on Reservation

   Mode 14 = Active/Standby Operating Mode

 

Profile name = OpenVMS

   Type = Standard Mode value = (00005073)

 

   Mode 0 = Peripheral Device LUN Addressing

   Mode 1 = Asymmetric Failover

   Mode 2 = Logical volumes connect as unavailable on Backup Controller

   Mode 3 = Product ID of 'MSA1000 VOLUME' (only if Active-Standby mode)

   Mode 4 = VMS shadow style bad block handling

   Mode 5 = Logout all initiators on TPRLO

   Mode 6 = Fault management events reported through Unit Attention

   Mode 7 = Do not send FCP response info with SCSI status

   Mode 8 = Do not send Unit Attention on failover

   Mode 9 = SCSI inquiry revision field contains the actual version

   Mode 10 = SCSI inquiry vendor ID='Compaq'

   Mode 11 = Power On Reset Unit Attention generated on FC Login or Logout

   Mode 12 = Enforce Force Unit Access on Write

   Mode 13 = Ignore Target Port on Reservation

   Mode 14 = Active/Standby Operating Mode

 

Profile name = Tru64

   Type = Standard Mode value = (00005163)

 

   Mode 0 = Peripheral Device LUN Addressing

   Mode 1 = Asymmetric Failover

   Mode 2 = Logical volumes connect as unavailable on Backup Controller

   Mode 3 = Product ID of 'MSA1000 VOLUME' (only if Active-Standby mode)

   Mode 4 = Normal bad block handling

   Mode 5 = Logout all initiators on TPRLO

   Mode 6 = Fault management events reported through Unit Attention

   Mode 7 = Do not send FCP response info with SCSI status

   Mode 8 = Send Unit Attention on failover

   Mode 9 = SCSI inquiry revision field contains the actual version

   Mode 10 = SCSI inquiry vendor ID='Compaq'

   Mode 11 = Power On Reset Unit Attention generated on FC Login or Logout

   Mode 12 = Enforce Force Unit Access on Write

   Mode 13 = Ignore Target Port on Reservation

   Mode 14 = Active/Standby Operating Mode

 

Profile name = Linux

   Type = Standard Mode value = (000050a7)

 

   Mode 0 = Peripheral Device LUN Addressing

   Mode 1 = Asymmetric Failover

   Mode 2 = Logical volumes connect as available on Backup Controller

   Mode 3 = Product ID of 'MSA1000 VOLUME' (only if Active-Standby mode)

   Mode 4 = Normal bad block handling

   Mode 5 = Logout all initiators on TPRLO

   Mode 6 = Fault management events not reported through Unit Attention

   Mode 7 = Send FCP response info with SCSI status

   Mode 8 = Do not send Unit Attention on failover

   Mode 9 = SCSI inquiry revision field contains the actual version

   Mode 10 = SCSI inquiry vendor ID='Compaq'

   Mode 11 = Power On Reset Unit Attention generated on FC Login or Logout

   Mode 12 = Enforce Force Unit Access on Write

   Mode 13 = Ignore Target Port on Reservation

   Mode 14 = Active/Standby Operating Mode

 

Profile name = Solaris

   Type = Standard Mode value = (000050a7)

 

   Mode 0 = Peripheral Device LUN Addressing

   Mode 1 = Asymmetric Failover

   Mode 2 = Logical volumes connect as available on Backup Controller

   Mode 3 = Product ID of 'MSA1000 VOLUME' (only if Active-Standby mode)

   Mode 4 = Normal bad block handling

   Mode 5 = Logout all initiators on TPRLO

   Mode 6 = Fault management events not reported through Unit Attention

   Mode 7 = Send FCP response info with SCSI status

   Mode 8 = Do not send Unit Attention on failover

   Mode 9 = SCSI inquiry revision field contains the actual version

   Mode 10 = SCSI inquiry vendor ID='Compaq'

   Mode 11 = Power On Reset Unit Attention generated on FC Login or Logout

   Mode 12 = Enforce Force Unit Access on Write

   Mode 13 = Ignore Target Port on Reservation

   Mode 14 = Active/Standby Operating Mode

 

Profile name = Netware

   Type = Standard Mode value = (000050a7)

 

   Mode 0 = Peripheral Device LUN Addressing

   Mode 1 = Asymmetric Failover

   Mode 2 = Logical volumes connect as available on Backup Controller

   Mode 3 = Product ID of 'MSA1000 VOLUME' (only if Active-Standby mode)

   Mode 4 = Normal bad block handling

   Mode 5 = Logout all initiators on TPRLO

   Mode 6 = Fault management events not reported through Unit Attention

   Mode 7 = Send FCP response info with SCSI status

   Mode 8 = Do not send Unit Attention on failover

   Mode 9 = SCSI inquiry revision field contains the actual version

   Mode 10 = SCSI inquiry vendor ID='Compaq'

   Mode 11 = Power On Reset Unit Attention generated on FC Login or Logout

   Mode 12 = Enforce Force Unit Access on Write

   Mode 13 = Ignore Target Port on Reservation

   Mode 14 = Active/Standby Operating Mode

 

Profile name = HP

   Type = Standard Mode value = (000058a6)

 

   Mode 0 = Volume Set Addressing

   Mode 1 = Asymmetric Failover

   Mode 2 = Logical volumes connect as available on Backup Controller

   Mode 3 = Product ID of 'MSA1000 VOLUME' (only if Active-Standby mode)

   Mode 4 = Normal bad block handling

   Mode 5 = Logout all initiators on TPRLO

   Mode 6 = Fault management events not reported through Unit Attention

   Mode 7 = Send FCP response info with SCSI status

   Mode 8 = Do not send Unit Attention on failover

   Mode 9 = SCSI inquiry revision field contains the actual version

   Mode 10 = SCSI inquiry vendor ID='Compaq'

   Mode 11 = No Power On Reset Unit Attention generated on FC Login or Logout

   Mode 12 = Enforce Force Unit Access on Write

   Mode 13 = Ignore Target Port on Reservation

   Mode 14 = Active/Standby Operating Mode

 

Profile name = XP Storage Array

   Type = Standard Mode value = (00005163)

 

   Mode 0 = Peripheral Device LUN Addressing

   Mode 1 = Asymmetric Failover

   Mode 2 = Logical volumes connect as unavailable on Backup Controller

   Mode 3 = Product ID of 'MSA1000 VOLUME' (only if Active-Standby mode)

   Mode 4 = Normal bad block handling

   Mode 5 = Logout all initiators on TPRLO

   Mode 6 = Fault management events reported through Unit Attention

   Mode 7 = Do not send FCP response info with SCSI status

   Mode 8 = Send Unit Attention on failover

   Mode 9 = SCSI inquiry revision field contains the actual version

   Mode 10 = SCSI inquiry vendor ID='Compaq'

   Mode 11 = Power On Reset Unit Attention generated on FC Login or Logout

   Mode 12 = Enforce Force Unit Access on Write

   Mode 13 = Ignore Target Port on Reservation

   Mode 14 = Active/Standby Operating Mode

 

 

CLI-2> show globals

 

Global Parameters:

   System Name:        MHSAN

   Rebuild Priority:   low

   Expand Priority:    high

   Surface Delay:      3.0 seconds

 

   Total Cache:        256MB

      50% Read Cache:  128MB

      50% Write Cache: 128MB

 

   Temperature:

          EMU: 24 Celsius,  75 Fahrenheit

          PS1: 23 Celsius,  73 Fahrenheit

          PS2: 23 Celsius,  73 Fahrenheit

 

CLI-2> show acl

 

ACL is disabled. To enable ACL use 'add acl'.

 

CLI-2> show connections

 

Connection Name: ESX_02_CONN_01

   Host WWNN = 50060B00-00C24CF9

   Host WWPN = 50060B00-00C24CF8

   Profile Name = Linux

   Unit Offset = 0

   Controller 2 Port 1 Status = Offline

   Controller 1 Port 1 Status = Online

 

Connection Name: ESX_03_CONN_01

   Host WWNN = 50060B00-00C23E67

   Host WWPN = 50060B00-00C23E66

   Profile Name = Linux

   Unit Offset = 0

   Controller 2 Port 1 Status = Offline

show disks   Controller 1 Port 1 Status = Online

 

 

Connection Name: ESX_01_CONN_01

   Host WWNN = 50060B00-00C2400F

   Host WWPN = 50060B00-00C2400E

   Profile Name = Linux

   Unit Offset = 0

   Controller 2 Port 1 Status = Offline

Disk List:   (box,bay)    (B:T:L)      Size     Speed    Units

show boxEnclosure 5:    SATA     (0:04:00)  PROLIANT 8LCE   2.02

 

   Disk501     (5,01)    (0:04:01)    750.1GB  160 MB/s  0, 1, 2

   Disk502     (5,02)    (0:04:02)    750.1GB  160 MB/s  0, 1, 2

   Disk503     (5,03)    (0:04:03)    750.1GB  160 MB/s  0, 1, 2

   Disk504     (5,04)    (0:04:04)    750.1GB  160 MB/s  0, 1, 2

   Disk505     (5,05)    (0:04:05)    750.1GB  160 MB/s  0, 1, 2

   Disk506     (5,06)    (0:04:06)    750.1GB  160 MB/s  0, 1, 2

   Disk507     (5,07)    (0:04:07)    750.1GB  160 MB/s  0, 1, 2

   Disk508     (5,08)    (0:04:08)    750.1GB  160 MB/s  3, 4

   Disk509     (5,09)    (0:04:09)    750.1GB  160 MB/s  3, 4

   Disk510     (5,10)    (0:04:10)    750.1GB  160 MB/s  3, 4

   Disk511     (5,11)    (0:04:11)    750.1GB  160 MB/s  3, 4

   Disk512     (5,12)    (0:04:12)    750.1GB  160 MB/s  0, 1, 2, 3, 4, 5, 6, 7, 8, 9 (spare)

Enclosure 7:    SATA     (2:04:00)  PROLIANT 8LCE   2.02

   Disk701     (7,01)    (2:04:01)    750.1GB  160 MB/s  5

   Disk702     (7,02)    (2:04:02)    750.1GB  160 MB/s  5

   Disk703     (7,03)    (2:04:03)    750.1GB  160 MB/s  6, 7

   Disk704     (7,04)    (2:04:04)    750.1GB  160 MB/s  6, 7

   Disk705     (7,05)    (2:04:05)    750.1GB  160 MB/s  6, 7

   Disk706     (7,06)    (2:04:06)    750.1GB  160 MB/s  6, 7

   Disk707     (7,07)    (2:04:07)    750.1GB  160 MB/s  8, 9

   Disk708     (7,08)    (2:04:08)    750.1GB  160 MB/s  8, 9

   Disk709     (7,09)    (2:04:09)    750.1GB  160 MB/s  8, 9

   Disk710     (7,10)    (2:04:10)    750.1GB  160 MB/s  8, 9

   Disk711     (7,11)    (2:04:11)    750.1GB  160 MB/s  8, 9

   Disk712     (7,12)    (2:04:12)    750.1GB  160 MB/s  0, 1, 2, 3, 4, 5, 6, 7, 8, 9 (spare)

 

Notes:

    The speed is the currently negotiated speed to the disk. This may

    be less than the maximum speed supported by the device due to bus

    faults, loss of signal integrity, etc.                          

 

Box #5:

SATA enclosure at bus 0 channel 1 target 4

   Firmware ID string: PROLIANT 8LCE  

   Firmware revision:  2.02

   Serial number:      E0AHMLJ191

Environmental Status:

   No alert conditions reported

Cache Information:

   Total Memory:       112MB

   Read Cache:         56MB

   Write Cache:        56MB

   Cache Status:       Enabled

   Battery #1 (lower): OK

   Battery #2 (upper): OK

 

Box #7:

SATA enclosure at bus 2 channel 1 target 4

   Firmware ID string: PROLIANT 8LCE  

   Firmware revision:  2.02

   Serial number:      E094MLJ18V

Environmental Status:

   No alert conditions reported

Cache Information:

   Total Memory:       112MB

   Read Cache:         56MB

   Write Cache:        56MB

   Cache Status:       Enabled

   Battery #1 (lower): OK

   Battery #2 (upper): OK

   Controller 1 Port 1 Status = Online

 

Connection Name: ESX_02_CONN_02

   Host WWNN = 50060B00-00C24129

   Host WWPN = 50060B00-00C24128

   Profile Name = Linux

   Unit Offset = 0

   Controller 2 Port 1 Status = Online

show units   Controller 1 Port 1 Status = Offline

 

 

Connection Name: ESX_01_CONN_02

   Host WWNN = 50060B00-00C240D3

   Host WWPN = 50060B00-00C240D2

   Profile Name = Linux

   Unit Offset = 0

   Controller 2 Port 1 Status = Online

 

Unit 0:

show this_controllerIn PDLA mode, Unit 0 is Lun 1; In VSA mode, Unit 0 is Lun 0.

 

Unit Identifier   :

Device Identifier : 600508B3-00948810-AA4809F9-C5570008

Preferred Path    : Controller 1 (other controller)

Cache Status      : Enabled

Max Boot Partition: Disabled

Volume Status     : VOLUME OK

Parity Init Status: Complete

7 Data Disk(s) used by lun 0:

   Disk501: Box 5, Bay 01, (B:T:L 0:04:01)

   Disk502: Box 5, Bay 02, (B:T:L 0:04:02)

   Disk503: Box 5, Bay 03, (B:T:L 0:04:03)

   Disk504: Box 5, Bay 04, (B:T:L 0:04:04)

   Disk505: Box 5, Bay 05, (B:T:L 0:04:05)

   Disk506: Box 5, Bay 06, (B:T:L 0:04:06)

   Disk507: Box 5, Bay 07, (B:T:L 0:04:07)

Spare Disk(s) used by lun 0:

   Disk512: Box 5, Bay 12, (B:T:L 0:04:12)

   Disk712: Box 7, Bay 12, (B:T:L 2:04:12)

Logical Volume Raid Level: DISTRIBUTED PARITY FAULT TOLERANCE (RAID 5)

                           stripe_size=64kB

Logical Volume Capacity : 2,097,151MB

 

Unit 1:

In PDLA mode, Unit 1 is Lun 2; In VSA mode, Unit 1 is Lun 1.

Unit Identifier   :

Device Identifier : 600508B3-00948810-A9881A04-F5EE0009

Preferred Path    : Controller 1 (other controller)

Cache Status      : Enabled

Max Boot Partition: Disabled

Volume Status     : VOLUME OK

Parity Init Status: Complete

7 Data Disk(s) used by lun 1:

   Disk501: Box 5, Bay 01, (B:T:L 0:04:01)

   Disk502: Box 5, Bay 02, (B:T:L 0:04:02)

   Disk503: Box 5, Bay 03, (B:T:L 0:04:03)

   Disk504: Box 5, Bay 04, (B:T:L 0:04:04)

   Disk505: Box 5, Bay 05, (B:T:L 0:04:05)

   Disk506: Box 5, Bay 06, (B:T:L 0:04:06)

   Disk507: Box 5, Bay 07, (B:T:L 0:04:07)

Spare Disk(s) used by lun 1:

   Disk512: Box 5, Bay 12, (B:T:L 0:04:12)

   Disk712: Box 7, Bay 12, (B:T:L 2:04:12)

Logical Volume Raid Level: DISTRIBUTED PARITY FAULT TOLERANCE (RAID 5)

                           stripe_size=64kB

Logical Volume Capacity : 2,097,151MB

 

Unit 2:

In PDLA mode, Unit 2 is Lun 3; In VSA mode, Unit 2 is Lun 2.

Unit Identifier   :

Device Identifier : 600508B3-00948810-A9C82A0D-2D39000A

Preferred Path    : Controller 1 (other controller)

Cache Status      : Enabled

Max Boot Partition: Disabled

Volume Status     : VOLUME OK

Parity Init Status: Complete

7 Data Disk(s) used by lun 2:

   Disk501: Box 5, Bay 01, (B:T:L 0:04:01)

   Disk502: Box 5, Bay 02, (B:T:L 0:04:02)

   Disk503: Box 5, Bay 03, (B:T:L 0:04:03)

   Disk504: Box 5, Bay 04, (B:T:L 0:04:04)

   Disk505: Box 5, Bay 05, (B:T:L 0:04:05)

   Disk506: Box 5, Bay 06, (B:T:L 0:04:06)

   Disk507: Box 5, Bay 07, (B:T:L 0:04:07)

Spare Disk(s) used by lun 2:

   Disk512: Box 5, Bay 12, (B:T:L 0:04:12)

   Disk712: Box 7, Bay 12, (B:T:L 2:04:12)

Logical Volume Raid Level: DISTRIBUTED PARITY FAULT TOLERANCE (RAID 5)

                           stripe_size=64kB

Logical Volume Capacity : 97,927MB

 

Unit 3:

In PDLA mode, Unit 3 is Lun 4; In VSA mode, Unit 3 is Lun 3.

Unit Identifier   :

Device Identifier : 600508B3-0094883A1C-669A000B

Preferred Path    : Controller 1 (other controller)

Cache Status      : Enabled

Max Boot Partition: Disabled

Volume Status     : VOLUME OK

Parity Init Status: Complete

4 Data Disk(s) used by lun 3:

   Disk508: Box 5, Bay 08, (B:T:L 0:04:08)

   Disk509: Box 5, Bay 09, (B:T:L 0:04:09)

   Disk510: Box 5, Bay 10, (B:T:L 0:04:10)

   Disk511: Box 5, Bay 11, (B:T:L 0:04:11)

Spare Disk(s) used by lun 3:

   Disk512: Box 5, Bay 12, (B:T:L 0:04:12)

   Disk712: Box 7, Bay 12, (B:T:L 2:04:12)

Logical Volume Raid Level: DISTRIBUTED PARITY FAULT TOLERANCE (RAID 5)

                           stripe_size=64kB

Logical Volume Capacity : 2,097,151MB

 

Unit 4:

In PDLA mode, Unit 4 is Lun 5; In VSA mode, Unit 4 is Lun 4.

Unit Identifier   :

Device Identifier : 600508B3-00948810-A5884A24-6CFC000D

Preferred Path    : Controller 1 (other controller)

Cache Status      : Enabled

Max Boot Partition: Disabled

Volume Status     : VOLUME OK

Parity Init Status: Complete

4 Data Disk(s) used by lun 4:

   Disk508: Box 5, Bay 08, (B:T:L 0:04:08)

   Disk509: Box 5, Bay 09, (B:T:L 0:04:09)

   Disk510: Box 5, Bay 10, (B:T:L 0:04:10)

   Disk511: Box 5, Bay 11, (B:T:L 0:04:11)

Spare Disk(s) used by lun 4:

   Disk512: Box 5, Bay 12, (B:T:L 0:04:12)

   Disk712: Box 7, Bay 12, (B:T:L 2:04:12)

Logical Volume Raid Level: DISTRIBUTED PARITY FAULT TOLERANCE (RAID 5)

                           stripe_size=64kB

Logical Volume Capacity : 48,963MB

 

Unit 5:

In PDLA mode, Unit 5 is Lun 6; In VSA mode, Unit 5 is Lun 5.

Unit Identifier   :

Device Identifier : 600508B3-00948810-A6CD2375-E7AF0008

Preferred Path    : Controller 1 (other controller)

Cache Status      : Enabled

Max Boot Partition: Disabled

Volume Status     : VOLUME OK

Mirror Init Status: Complete

2 Data Disk(s) used by lun 5:

   Disk701: Box 7, Bay 01, (B:T:L 2:04:01)

   Disk702: Box 7, Bay 02, (B:T:L 2:04:02)

Spare Disk(s) used by lun 5:

   Disk512: Box 5, Bay 12, (B:T:L 0:04:12)

   Disk712: Box 7, Bay 12, (B:T:L 2:04:12)

Logical Volume Raid Level: MIRROR FAULT TOLERANCE (RAID 1)

                           stripe_size=128kB

Logical Volume Capacity : 715,372MB

 

Unit 6:

In PDLA mode, Unit 6 is Lun 7; In VSA mode, Unit 6 is Lun 6.

Unit Identifier   :

Device Identifier : 600508B3-00948810-A87D191B-7A540009

Preferred Path    : Controller 1 (other controller)

Cache Status      : Enabled

Max Boot Partition: Disabled

Volume Status     : VOLUME OK

Parity Init Status: Complete

4 Data Disk(s) used by lun 6:

   Disk703: Box 7, Bay 03, (B:T:L 2:04:03)

   Disk704: Box 7, Bay 04, (B:T:L 2:04:04)

   Disk705: Box 7, Bay 05, (B:T:L 2:04:05)

   Disk706: Box 7, Bay 06, (B:T:L 2:04:06)

Spare Disk(s) used by lun 6:

   Disk512: Box 5, Bay 12, (B:T:L 0:04:12)

   Disk712: Box 7, Bay 12, (B:T:L 2:04:12)

Logical Volume Raid Level: DISTRIBUTED PARITY FAULT TOLERANCE (RAID 5)

                           stripe_size=64kB

Logical Volume Capacity : 2,097,151MB

 

Unit 7:

In PDLA mode, Unit 7 is Lun 8; In VSA mode, Unit 7 is Lun 7.

Unit Identifier   :

Device Identifier : 600508B3-00948810-AE1D092C-D2DF000A

Preferred Path    : Controller 1 (other controller)

Cache Status      : Enabled

Max Boot Partition: Disabled

Volume Status     : VOLUME OK

Parity Init Status: Complete

4 Data Disk(s) used by lun 7:

   Disk703: Box 7, Bay 03, (B:T:L 2:04:03)

   Disk704: Box 7, Bay 04, (B:T:L 2:04:04)

   Disk705: Box 7, Bay 05, (B:T:L 2:04:05)

   Disk706: Box 7, Bay 06, (B:T:L 2:04:06)

Spare Disk(s) used by lun 7:

   Disk512: Box 5, Bay 12, (B:T:L 0:04:12)

   Disk712: Box 7, Bay 12, (B:T:L 2:04:12)

Logical Volume Raid Level: DISTRIBUTED PARITY FAULT TOLERANCE (RAID 5)

                           stripe_size=64kB

Logical Volume Capacity : 48,963MB

 

Unit 8:

In PDLA mode, Unit 8 is Lun 9; In VSA mode, Unit 8 is Lun 8.

Unit Identifier   :

Device Identifier : 600508B3-00948810-ADDDF94C-2B84000B

Preferred Path    : Controller 1 (other controller)

Cache Status      : Enabled

Max Boot Partition: Disabled

Volume Status     : VOLUME OK

Parity Init Status: Complete

5 Data Disk(s) used by lun 8:

   Disk707: Box 7, Bay 07, (B:T:L 2:04:07)

   Disk708: Box 7, Bay 08, (B:T:L 2:04:08)

   Disk709: Box 7, Bay 09, (B:T:L 2:04:09)

   Disk710: Box 7, Bay 10, (B:T:L 2:04:10)

   Disk711: Box 7, Bay 11, (B:T:L 2:04:11)

Spare Disk(s) used by lun 8:

   Disk512: Box 5, Bay 12, (B:T:L 0:04:12)

   Disk712: Box 7, Bay 12, (B:T:L 2:04:12)

Logical Volume Raid Level: DISTRIBUTED PARITY FAULT TOLERANCE (RAID 5)

                           stripe_size=64kB

Logical Volume Capacity : 2,097,151MB

 

Unit 9:

In PDLA mode, Unit 9 is Lun 10; In VSA mode, Unit 9 is Lun 9.

Unit Identifier   :

Device Identifier : 600508B3-00948810-AC9DE95D-8741000C

Preferred Path    : Controller 1 (other controller)

Cache Status      : Enabled

Max Boot Partition: Disabled

Volume Status     : VOLUME OK

Parity Init Status: Complete

5 Data Disk(s) used by lun 9:

   Disk707: Box 7, Bay 07, (B:T:L 2:04:07)

   Disk708: Box 7, Bay 08, (B:T:L 2:04:08)

   Disk709: Box 7, Bay 09, (B:T:L 2:04:09)

   Disk710: Box 7, Bay 10, (B:T:L 2:04:10)

   Disk711: Box 7, Bay 11, (B:T:L 2:04:11)

Spare Disk(s) used by lun 9:

   Disk512: Box 5, Bay 12, (B:T:L 0:04:12)

   Disk712: Box 7, Bay 12, (B:T:L 2:04:12)

Logical Volume Raid Level: DISTRIBUTED PARITY FAULT TOLERANCE (RAID 5)

                           stripe_size=64kB

Logical Volume Capacity : 764,337MB

Controller 2 (left controller):

MSA1500(c) Hewlett-Packard PB9840TX3UQ033 Version 5.20 Build 1500 Hardware A

Build Time: 2007-01-24 16:03:28

   Component Enclosure.

   Controller Identifier:

   NODE_ID = 500508B3-00948810

   SCSI_VERSION = SCSI-3

   Supported Redundancy Mode: Active/Standby Asym-Active/Active

   Current Redundancy Mode: Active/Standby (emulated)

   Current Role:            Standby

   Device Port SCSI address 7

   Terminal speed for the CLI is set to 19200.

Host Port_1:

   REPORTED PORT_ID 500508B3-00948819

   PORT_1_TOPOLOGY = F_Port

Cache:

   128 megabyte read cache   128 megabyte write cache  Version 2

   Cache is GOOD, and Cache is enabled.

   No unflushed data in cache

   Batteries are disabled

   Module #1 is fully charged and turned off.

Controller Up Time:

   13 Days 20 Hours 16 Minutes 21 Seconds

Health:

   Surface Scan:   Complete.

   Rebuild Status: Complete.

   Expansion:      Complete.

   Controller 1 Port 1 Status = Offline

 

Connection Name: ESX_03_CONN_02

   Host WWNN = 50060B00-00C23CAB

   Host WWPN = 50060B00-00C23CAA

   Profile Name = Linux

   Unit Offset = 0

   Controller 2 Port 1 Status = Online

show other_controller   Controller 1 Port 1 Status = Offline

 

 

CLI-2> Controller 1 (right controller):

MSA1500(c) Hewlett-Packard PB9840TX3UK04Z Version 5.20 Build 1500 Hardware A

Build Time: 2007-01-24 16:03:28

   Component Enclosure.

   Controller Identifier:

   NODE_ID = 500508B3-00948810

   SCSI_VERSION = SCSI-3

   Supported Redundancy Mode: Active/Standby Asym-Active/Active

   Current Redundancy Mode: Active/Standby (emulated)

   Current Role:            Active

   Device Port SCSI address 6

   Terminal speed for the CLI is set to 19200.

Host Port_1:

   REPORTED PORT_ID 500508B3-00948811

   PORT_1_TOPOLOGY = F_Port

Cache:

   128 megabyte read cache   128 megabyte write cache  Version 2

   Cache is GOOD, and Cache is enabled.

   Unflushed data in cache

   Batteries are enabled

   Module #1 is fully charged and turned on.

Controller Up Time:

   13 Days 20 Hours 14 Minutes 45 Seconds

Health:

   Surface Scan:   Complete.

   Rebuild Status: Complete.

   Expansion:      Complete.

show eventlog

         TIME  CLASS  SUB DETL MESSAGE

 

CLI-2> 0d 00:01:28.7   0006 0000 0000 Redundant operation state change.

show preferred_path0d 00:02:23.6   0006 0000 0000 Redundant operation state change.

 

 

 

 

CLI-2> Controller 1 (other_controller) is the current optimal path for these units:

  show auto_path_change0

,1,2,3,4,5,6,7,8,9

Controller 2 (this_controller) is the current optimal path for these units:

  None

Implicit (automatic load-based) LUN ownership changes are currently ENABLED.

 

 

 
 

Advertisement